Effect of depth and distance of the borehole from the septic tank on the physico-chemical quality of water

dc.contributor.authorChove, Lucy Mlipano
dc.contributor.authorMongi, Richard
dc.contributor.authorChenge, Lawrence
dc.date.accessioned2023-03-06T11:37:37Z
dc.date.available2023-03-06T11:37:37Z
dc.date.issued2017-12-28
dc.descriptionJournal articleen_US
dc.description.abstractA study to examine the effect of depth and distance of the boreholes from the septic tank on physico-chemical parameters of the borehole water consumed in Dar Es Salaam, Tanzania was conducted. Samples were collected from 48 boreholes in Ilala, Kinondoni and Temeke districts and subjected to pH, B.O.D (Biological Oxygen Demand), total hardness, copper and lead analyses in relation to safety and quality levels set by WHO and TBS. Analysis by R-statistics indicated that pH and B.O.D significantly (p<0.05) decreased as the depth of borehole increased, whereas total hardness was significantly (p<0.05) higher in very deep boreholes than the other heights. Total hardness and pH were not significantly (p>0.05) affected by distance between septic tank and borehole and the B.O.D levels were significantly higher in the borehole water situated near the septic tank than those which were far. Based on the physico-chemical characteristics of water, 25% of the samples did not comply with WHO and TBS specification limits while 75% complied, most of which had shallow depths and were situated near the septic tank. It may thus be concluded that both the distance and the depth between septic tank and borehole influenced physico-chemical characteristics of water.en_US
dc.identifier.issn2166-1073
dc.identifier.urihttp://www.suaire.sua.ac.tz/handle/123456789/4985
dc.language.isoenen_US
dc.publisherMacrothink Instituteen_US
dc.subjectB.O.Den_US
dc.subjectCopperen_US
dc.subjectLeaden_US
dc.subjectpHen_US
dc.subjectTotal hardnessen_US
dc.titleEffect of depth and distance of the borehole from the septic tank on the physico-chemical quality of wateren_US
dc.typeArticleen_US
dc.urlhttps://doi.org/10.5296/jfs.v7i1.12187en_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
12 - Chenge Mongi and Lucy - JFS - Effect of distance from borehole on water quality -.pdf
Size:
263.53 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.67 KB
Format:
Item-specific license agreed upon to submission
Description: