Sokoine University of Agriculture

A simple and sensitive method for the detection of “Oxytetracycine” levels in ready-to-eat beef by liquid chromatography-mass spectrometry

Show simple item record

dc.contributor.author Mgonja, F.
dc.contributor.author Mosha, R.
dc.contributor.author Mabiki, F.
dc.contributor.author Choongo, K.
dc.date.accessioned 2018-08-10T11:12:13Z
dc.date.available 2018-08-10T11:12:13Z
dc.date.issued 2016-07
dc.identifier.issn 1996-0816
dc.identifier.uri https://www.suaire.sua.ac.tz/handle/123456789/2583
dc.description African Journal of Pharmacy and Pharmacology, 2016; 10 (28): 571-579 en_US
dc.description.abstract Antimicrobial drug residues have emerged as one of the public health problems worldwide. In this study, a modified sensitive liquid chromatography mass spectrometry (LC-MS) method to detect the “Oxytetracycine” (OTC) levels in ready-to-eat beef meat in Tanzania was evaluated. Beef samples were extracted in acetonitrile in ethylenediaminetetraacetic acid (EDTA) buffer (pH 4), followed by cleaning up with Supelclean ENVI-carb active coal and a stream of nitrogen gas. The wavelength of the diode array detector (DAD) was set at 275 and 355 nm. The detection limit of the method was calculated as 18.2 ng/g and the recovery rate of OTC was 78.6%. A total of 45 ready-to-eat beef meat samples were analyzed, with 16 (35.5%) and 29 (64.5%) barbequed and boiled samples, respectively. Of the 45 samples, 35 (77.8%) samples had OTC residues while 9 (25.7%) samples had violative residue levels above the maximum residue limits recommended by the Food and Agriculture Organization and the World Health Organization. The highest concentration was 545.2 ng/g. Therefore, withdrawal period and proper use of antibiotics for animal production should be of concern as consumers are at risk of adverse effects due to consumption of unacceptable levels of drug residues and a risk of developing microbial resistance. To the best knowledge of the authors, this is the first study to evaluate LC-MS method to detect the OTC levels in ready-to-eat beef meat in Tanzania en_US
dc.language.iso en en_US
dc.publisher African Journal of Pharmacy and Pharmacology en_US
dc.subject Oxytetracycline en_US
dc.subject High performance liquid chromatography en_US
dc.subject Mass spectrometry en_US
dc.subject Ready-to-eat beef meat en_US
dc.subject Residues en_US
dc.title A simple and sensitive method for the detection of “Oxytetracycine” levels in ready-to-eat beef by liquid chromatography-mass spectrometry en_US
dc.type Article en_US
dc.url http://www.academicjournals.org/AJPP en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUA IR


Browse

My Account

Statistics